Modell nr: CA35T
Märke: Brando
Power: Solenoid
Connection Type: Threaded
Structure: Diaphragm
Valve Type: Right Angle
Voltage: AC24V, AC110V, AC220V, DC24V
Media: Air
Port Size: G1-1/4''
Aperture Of Flow Retea: 35mm
Pressure: 0.3~0.8Mpa
Temperature: -5℃ - 55℃
Förpackning: lådor, kartonger, pallar
Produktivitet: 100000pcs per month
Transportfordon: Ocean,Land,Air
Hemorten: Ningbo, Kina
Stödja: 100000pcs per month
Certifikat: CE.ISO
Hamn: Ningbo,Shanghai,Guangzhou
Betalning Typ: L/C,T/T,Paypal
Incoterm: FOB,CFR,CIF
CA35T gängad dammsamlare membranventil
CA35T goyen typ dammsamlare pulsstråleventil spelar en viktig roll i pulsjet dammsamlare Systerm. Det är rätt vinkeltyp 'T' -serie. Vi har också annan anslutningstyp, som rätt vinkeltyp med Dresser Nut 'DD' Type, Manifold Mount 'Mm' Type and Flanged 'FS' Type.
Pulsdammavlägsningsventilen använder kolv med rostfritt stål, som är tryckbeständiga och slitstödda och har en livslängd på miljoner gånger. Det är en tryckluft "switch" av pulspåsen dammavlägsnande och blåssystem i dammväskan och tar emot pulssignaler för att säkerställa dammsamlarens prestanda. Motståndet är i uppsättningsområdet, vilket säkerställer dammsamlarens bearbetningskapacitet och absorptionseffektivitet.
Tekniska data för CA 35T magnetventil :
Model No. | CA35T |
Port Size | G1-1/4'' |
Nornimal Size |
Φ35mm |
Action Type | Pilot Operated |
Valve Type | Right Angle |
Number of Diaphrgam | 1 |
TEMP Range |
-5℃ - 55℃ |
Pressure | 0.3~0.8Mpa |
Seal Material | NBR (common) , all available |
Body Material | Aluminum ADC12 |
Dekonstruktion av Ca35T elektromagnetisk pulventil :
Part Name | Material |
Solenoid Coil | Copper Wire |
Armature Assembly | Stainless Steel |
Spring | Stainless Steel |
Seals & Diaphragm | NBR (common), all available |
Body | Die-casting Aluminum Alloy |
1.Valver läckor eller stängs inte snabbt
phenomenon |
Reason |
Solution |
Solenoid Coil Hot |
Solenoid Coil Hot |
Measure whether the coil is energized normally. Check the pulse signal control system to correct incorrect connections |
No power to the coil |
1. Diaphragm rupture 2. The diaphragm surface is dirty and cannot be sealed 3. Hole in blowpipe (submerged) |
1. Repalce Diaphragm 2. Clean diaphragm surface 3. Repair or replace blowpipe |
Broken spring, broken diaphragm |
1.Insufficient air supply after spraying, valve cannot be closed quickly 2.Plunger crooked, diaphragm does not reset properly 3.The coil is energized for a long time, which produces electromagnetic memory |
1. Connect small air bags into a large capacity; Thickened pipe 2. repalce plunger 3. Detect pulse input , repalce solenoid coil |
phenomenon |
Reason |
Solution |
Solenoid coil does not work |
1. Voltage mismatch 2. The solenoid is not powered or burned 3. Plunger Crooked 4. Spring misalignment is stuck |
1. Check if the voltage matches; Replace the pulse control system 2. Repalce solenoid coil 3. Repalace plunger 4. Replace component or reinstall small spring in plunger |
solenoid coil working, but Valve does not blow |
air hole blocked |
Installation cleaning filter |